Specifications are subject to change without notice (17.08.2018) 1
Rated operating dist. (Sn)
CA18CLF08 3 to 8 mm
factory set at 8 mm
CA18CLN12 3 to 12 mm
factory set at 12 mm
Sensitivity Adj. 270° turn pot. meter
Effective operation dist. (Sr) 0.9 x Sn ≤ Sr ≤ 1.1 x Sn
Usable operation dist. (Su) 0.8 x Sr ≤ Su ≤ 1.2 x Sr
Repeat accuracy (R) ≤ 5%
Hysteresis (H)
4 to 20% of sensing distance
Rated operational volt. (UB) 20 to 250 VAC (ripple incl.)
Ripple ≤ 10%
Rated operational current (Ie)
Continuous ≤ 500 mA
Short-time < 2.5 A (max. 20 ms)
Min. load current 10 mA
Voltage drop (Ud) ≤ 10 VAC (at loads ≥ 20 mA)
Protection Transients
Power ON delay ≤ 100 ms
Freq. of operating cycles (f) 10 Hz
Indication for output ON LED, yellow
Environment
Degree of protection IP 67 (Nema 1, 3, 4, 6, 13)
Temperature
Operating temperature
-25° to +80°C ( -13° to +176°F)
Storage temperature
-40° to +85°C (-40° to +185°F)
Housing material
Body Grey, thermoplastic polyester
Front Grey, polyester
Cable end Polyester
Nuts Black, reinforced nylon
Connection
Cable Grey, 2 m, 2 x 0.5 mm2
Oil proof PVC
Plug (M6) M12 x 1, double keyed
Cable for plug (M6) CON.6A-series
Weight
Cable version 110 g
Plug version 30 g
Approvals
UL, CSA
CE-marking Yes
Type Selection
Product Description
Proximity Sensors Capacitive
Thermoplastic Polyester Housing
Type CA, M18, AC
• Featuring TRIPLESHIELDsensor protection
Rated operational voltage: 20-250 VAC
Adjustable sensing distance 3-8 mm or 3-12 mm
Output: SCR
Make or break switching function
LED indication
High noise immunity
Flush and non-flush types
Plug and cable versions
DC versions in the same housing
Capacitive proximity switc h es
with either sensing distance
8 mm flush mounted in metal
or sensing distance 12 mm
non-flush mounted. 2-wire AC
output with ma ke (NO) or bre-
ak (NC) switch ing. Grey M18
polyester housing with 2 m
PVC cable or M12 plug. Ideal
for use in level and plas tic
ma chin ery applica tions.
Housing Rated Mounting Ordering no. Ordering no. Ordering no. Ordering no.
diameter operating SCR/cable SCR/plug SCR/cable SCR/plug
dist. (Sn) 1) Make Make Break Break
switching switching switching switching
M18 8 mm
Flush (built-in)
CA18CLF08TO CA18CLF08TOM6 CA18CLF08TC CA18CLF08TCM6
M18 12 mm Non-flush CA18CLN12TO CA18CLN12TOM6 CA18CLN12TC CA18CLN12TCM6
1) Object: Grounded steel plate
Specifications
TRIPLESHIELD
Capacitive proximity switch
Housing style
Housing size
Housing material
Housing length
Detection principle
Sensing distance
Output type
Output configuration
Connection type
Ordering Key CA18CLN12TOM6
CARLO GAVAZZI i, j. _ WV \kg —1 F- : |—- LED \ tn
2 Specifications are subject to change without notice (17.08.2018)
Wiring Diagrams
EC, M18, AC
Max.
Min.
Sensitivity
The environments in which
capacitive sensors are install-
ed can often be un
stable re-
garding temperature, humi dity ,
object distance and industrial
(noise) interference. Because
of this, Carlo Ga vazzi offers
as standard features in all
TRIP LESHIELD™ capacitive
sensors a user-friendly sen-
sitivity adjustment instead of
having a fixed sensing range,
extend ed sen sing range to
accommodate mechanically
demand ing are as, temperatu-
re stability to en sure minimum
need for adjusting sensitivity
if temperature varies and high
immunity to elec tro magnetic
interference (EMI).
Note:
Sensors are factory set (de-
fault) to maximum rated sen-
sing range.
Adjustment Guide
Installation Hints
Capacitive sensors have the
unique ability to detect al-
most all materials, either in li-
quid or solid form. Capa ci tive
sensors can detect metallic
as well as non-metallic ob-
jects, how ever, their traditi-
onal use is for non-metallic
materials such as:
Plastic Industry
Resins, regrinds or moul-
ded products.
Chemical Industry
Cleansers, fertilisers, liquid
soaps, corrosives and pe-
trochemicals.
Wood Industry
Saw dust, paper products,
door and window
frames.
Ceramic & Glass
Industry
Raw material, clay or finish-
ed products, bottles.
Packaging Industry Pac-
kage inspection for level or
contents, dry goods, fruits
and vegetables, dairy pro-
ducts.
Materials are detected due
to their dielectric constant.
The bigger the size of an
object, the higher the den-
sity of material, the better
or easier it is to detect the
object. Nominal sensing di-
stan ce for a capacitive sen-
sor is referenced to a groun-
ded me tal plate (ST37).
For addi tional information
regarding di elec tric ratings
of materials please re fer to
Technical Information.
Dimensions
1)
M12 x 1
1)
1
3
2
CA18CL...
1) Note: Only CA18CLN CA18CLxxxTC CA18CLxxxTO
BU (2) BU (2)
BN (3) BN (3)
Relief of cable strain Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/
current peaks, separate the prox. switch pow-
er cables from any other power cables, e.g.
motor, contactor or solenoid cables Incorrect
Correct
The cable should not be pulled A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the
cable should be avoided
CARLO GAVAZZI V
Specifications are subject to change without notice (17.08.2018) 3
Delivery Contents
Capacitive switch: CA18CL...
Screw driver
2 nuts
• Packaging: Cardboard box
Installation & Adjustment Guide
Accessories
Plugs CON.6A-..series.
EC, M18, AC