Showing
of 28
Compare
Mfr Part #
Quantity Available
Price
Series
Package
Product Status
Type
Input Range
Output
Isolation
Response Time
Accuracy
Voltage - Supply
Mounting Type
Termination Style
Operating Temperature
Approval Agency
2308027
2308030
TRANSDUCER CURRENT 24VDC
Phoenix Contact
4
In Stock
1 : $324.01000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 200A4 ~ 20mA300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
2906242
2906242
TRANSDUCER VOLTAGE 24VDC
Phoenix Contact
0
In Stock
26
Factory
Check Lead Time
1 : $442.62000
Bulk
Bulk
ActiveVoltage Transducer±660VDC±10V5300VAC (Test)16ms-24VDCDIN RailScrew Terminal-25°C ~ 60°CCE, cULus
2813486
2813486
TRANSDUCER CURRENT 20-30VDC
Phoenix Contact
4
In Stock
23
Factory
1 : $341.13000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 100A4 ~ 20mA5000VAC (Test)340ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, cULus
2810612
2810612
TRANSDUCER CURRENT 24VDC
Phoenix Contact
0
In Stock
Check Lead Time
1 : $309.85000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 5A0 ~ 20mA4000VAC (Test)--24VDCDIN RailScrew Terminal-20°C ~ 60°CATEX, cULus
2813473
2813473
TRANSDUCER CURRENT 20-30VDC
Phoenix Contact
2
In Stock
1 : $309.85000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 400A0 ~ 10VDC5000VAC (Test)340ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, cULus
MACX MCR-SL-CAC-12-I-UP
2810638
MACX MCR-SL-CAC-12-I-UP
Phoenix Contact
5
In Stock
1 : $326.96000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 12A0 ~ 20mA4000VAC (Test)200ms-19.2 ~ 253VAC/DCDIN RailScrew Terminal-20°C ~ 65°CATEX, EAC
2810625
2810625
TRANSDUCER CURR 19.2-253VAC/DC
Phoenix Contact
9
In Stock
1 : $359.42000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 5A0 ~ 20mA4000VAC (Test)200ms-19.2 ~ 253VAC/DCDIN RailScrew Terminal-20°C ~ 65°CATEX, cULus
TRANSDUCER CURRENT 24VDC
2308085
TRANSDUCER CURRENT 24VDC
Phoenix Contact
8
In Stock
1 : $414.89000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 500A4 ~ 20mA300VAC (Working), 3500VAC (Test)150ms-24VDCDIN RailSpring Terminal-40°C ~ 65°CCE, cULus
2308027
2308108
TRANSDUCER CURRENT 24VDC
Phoenix Contact
0
In Stock
Check Lead Time
1 : $311.62000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 100A0 ~ 10VDC300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
2308027
2308027
TRANSDUCER CURRENT 24VDC
Phoenix Contact
0
In Stock
Check Lead Time
1 : $324.01000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 100A4 ~ 20mA300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
2814715
2814715
TRANSDUCER CURRENT 20-30VDC
Phoenix Contact
0
In Stock
Check Lead Time
1 : $523.35000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 11A±10VDC, 0 ~ 20mA300VAC (Working), 4000VAC (Test)40ms, 330ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, cULus
2814731
2814731
TRANSDUCER CURRENT 20-30VDC
Phoenix Contact
0
In Stock
Check Lead Time
1 : $580.32000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 11A±10VDC, 0 ~ 20mA300VAC (Working), 4000VAC (Test)40ms, 330ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, cULus
2813457
2813457
TRANSDUCER CURRENT 20-30VDC
Phoenix Contact
1
In Stock
20
Factory
1 : $309.85000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 100A0 ~ 10VDC, 0 ~ 20mA5000VAC (Test)340ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, cULus
2813460
2813460
TRANSDUCER CURRENT 20-30VDC
Phoenix Contact
1
In Stock
1 : $309.85000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 200A0 ~ 10VDC5000VAC (Test)340ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, cULus
2308027
2308043
TRANSDUCER CURRENT 24VDC
Phoenix Contact
1
In Stock
1 : $329.90000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 300A4 ~ 20mA300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
2813499
2813499
TRANSDUCER CURRENT 20-30VDC
Phoenix Contact
1
In Stock
1 : $341.13000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 200A4 ~ 20mA5000VAC (Test)340ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, cULus
2308027
2308072
TRANSDUCER CURRENT 24VDC
Phoenix Contact
1
In Stock
1 : $403.09000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 400A4 ~ 20mA300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
2308027
2308098
TRANSDUCER CURRENT 24VDC
Phoenix Contact
0
In Stock
Check Lead Time
1 : $403.09000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 600A4 ~ 20mA300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
2906243
2906243
TRANSDUCER VOLTAGE 24VDC
Phoenix Contact
0
In Stock
Check Lead Time
1 : $442.62000
Bulk
Bulk
ActiveVoltage Transducer±660VDC±10V5300VAC (Test)16ms-24VDCDIN RailSpring Terminal-25°C ~ 60°CCE, cULus
2814728
2814728
TRANSDUCER CURRENT 20-30VDC
Phoenix Contact
1
In Stock
1 : $523.35000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 55A±10VDC, 0 ~ 20mA300VAC (Working), 4000VAC (Test)40ms, 330ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, cULus
2813509
2813509
TRANSDUCER CURRENT 20-30VDC
Phoenix Contact
1
In Stock
1 : $341.13000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 400A4 ~ 20mA5000VAC (Test)340ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, cULus
EV-RCM-C1-AC30-DC6
1622450
EV-RCM-C1-AC30-DC6
Phoenix Contact
0
In Stock
9
Factory
Check Lead Time
1 : $325.52000
Bulk
-
Bulk
ActiveCurrent Transducer50A5A-70ms-100 ~ 240VACDIN RailSpring Terminal-25°C ~ 80°CCE
2308027
2308302
TRANSDUCER CURRENT 24VDC
Phoenix Contact
0
In Stock
Check Lead Time
1 : $342.90000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 300A0 ~ 10VDC300VAC (Working), 3500VAC (Test)150ms-24VDCChassis Mount, DIN RailSpring Terminal-40°C ~ 65°CCE, cULus
MCR-S-20-100-UI-DCI
2908798
MCR-S-20-100-UI-DCI
Phoenix Contact
0
In Stock
Check Lead Time
1 : $462.89000
Bulk
Bulk
ActiveCurrent Transducer0 ~ 100A±10VDC, 0 ~ 20mA300VAC (Working), 4000VAC (Test)40ms, 330ms-20 ~ 30VDCDIN RailScrew Terminal-20°C ~ 60°CCE, UL
2811103
2811103
TRANSDUCER VOLTAGE 18.5-30.2VDC
Phoenix Contact
0
In Stock
Obsolete
Bulk
ObsoleteAC Voltage Transducer0 ~ 440VAC0 ~ 10VDC, 0 ~ 20mA440VAC (Working), 3300VAC (Test)--18.5 ~ 30.2VDCDIN RailSpring Terminal-25°C ~ 60°CCE, cULus
Showing
of 28

Monitor - Current/Voltage Transducer


Industrial current or voltage transducers are used to monitor variable or non-sinusoidal sources, trigger peripheral devices in phase-fired control systems, monitor ground current, and other voltage or current monitoring applications. Output types include analog voltage or current, and positive and negative fixed voltages with accuracy from 0.2 to 2%.