Power Relays Selector Chart Datasheet by Panasonic Electric Works

ms M1 1 k;
 Panasonic Corporation 2018 ASCTB366E 201808
1
Power Relays (Over 2A) Selector Chart
Category Power Relays (Over 2A)
Product name S RELAY LA RELAY LD-P RELAY
Type of relay
(Height includes standoff unit = mm)
10.410.4
28
28 12
12
2525
2424 1212
15.315.3
7.2
7.2
20.520.5
Features 2a2b/3a1b/4a
4A polarized power relays
TV-4 rated (High capacity type)
2 Form A 3A/5A power relays
1 Form A 5A slim
power relays
Contact
data
Contact arrangement 2a2b, 3a1b, 4a2a1a
Contact shape Twin Single Single
Contact material Double layer contact of
AgNi-AgSnO2 type +Au clad
AgNi type +Au clad
AgSnO2 type AgNi type
Contact rating
(resistive)
Min. switching load
(reference value)
Max.switching voltage 250 V AC, 48 V DC 125 V AC 277 V AC 277 V AC, 30 V DC
Latching types availability ●−−
Coil data
Rated coil voltage 3, 5, 6, 12, 24, 48 V DC 12, 24 V DC 5, 6, 9, 12, 18, 24 V DC
Rated operating power 200 mW 530 mW 200 mW
Operate [Set] voltage (initial)
Max.70% V Max.75% V Max.75% V
Release [Reset] voltage (initial)
Min.10% V [Max.70% V] Min.5% V Min.5% V
Time
Characteristics
(initial)
Operate [Set] time (initial)
Max.15 ms Max.15 ms Max.10 ms
Release [Reset] time (initial)
Max.10 ms [Max.15 ms] Max.15 ms Max.10 ms
Expected
life
Mechanical Min.108Min.106Min.5 x106
Electrical Min.105 (AC)
Min.2 x105 (DC) Min.5 x104
Min.2 x10
5
(5 A 125 V AC)
Min.10
5
(5 A 250 V AC, 3 A 30 V DC)
Dielectric
strength
(initial)
Between open contacts 750 Vrms 1,000 Vrms 750 Vrms
Between contact sets 1,000 Vrms 1,000 Vrms
Between contact and coil 1,500 Vrms 4,000 Vrms 4,000 Vrms
Surge withstand voltage
(between contact and coil) (initial) 10,000 V 10,000 V
Ambient temperature -55 to +65-40 to +70-40 to +85
Protective
construction
Dust cover type −−−
Flux-resistant type −●−
Sealed type ●−●
Dimensions
Height (mm) Including standoff 10.4 25 15.3
Area of base (mm)
28
12
12
2424
7.2
20.520.5
PC board pattern (BOTTOM VIEW)
indicates input terminal
2.54mm grid
12φ1.3
Single Stable
15 5
7.5
2φ0.9 4φ1.311.5 7
4.7
(1.05)
(1.15)
4
φ
1.1
Safety standards UL, CSA UL, CSA, TÜV, VDE UL/C-UL, VDE, CQC
Unit weight (Approx.) 8 g 13 g 4 g
Option Socket − −
Remarks −−−
Initial of part number AG3 ALA ALDP
[Order of products: Max.contact rating (small to large)]
30 A
20 A
15 A
10 A
8 A
5 A
3 A
4 A 250 V AC
3 A 30 V DC
100
μ
A 100 mV DC
5 A 277 V AC
100 mA 5 V DC
3 A 125 V AC
100 mA 5 V DC
3 A 30 V DC
5 A 277 V AC
100 mA 5 V DC
Panasonic Corporation
Electromechanical Control Business Division
industrial.panasonic.com/ac/
, m fi—F 3mm Z( sml 2 am 2 mm 2 mm 1
Power Relays (Over 2A) Selector Chart
 Panasonic Corporation 2018 ASCTB366E 201808
2
Panasonic Corporation
Electromechanical Control Business Division
industrial.panasonic.com/ac/
Category Power Relays (Over 2A)
Product name LK-T RELAY NC RELAY PA-N RELAY
Type of relay
(Height includes standoff unit = mm)
2525
24
24 11
11
10.910.9
25.4
25.4
25.425.4
27.827.8
11.2
11.2
25.425.4
Flat (2c)
Slim (2c)
12.512.5
55
2020
Features TV-8 rated
1 Form A 8A power relays
Transistor drive
2c/4c 5A slim power relays
1 form A 5A Slim power relay
meet IEC61010 reinforced insulation
Contact
data
Contact arrangement 1a2c, 4c1a
Contact shape Single Twin Twin
Contact material AgSnO2 type AgNi type +Au clad AgNi type +Au
Contact rating
(resistive)
Min. switching load
(reference value)
Max.switching voltage 277 V AC 250 V AC, 220 V DC 250 V AC, 110 V DC (0.4 A)
Latching types availability −−−
Coil data
Rated coil voltage 5, 9, 12, 24 V DC 3, 5, 6, 12, 24, 48, 100 V DC 3, 4.5, 5, 6, 9, 12, 18, 24 V DC
Rated operating power 250 mW 360 mW (2c)*2, 720 mW (4c) 110 mW
Operate [Set] voltage (initial)
Max.70% V Max.80% V Max.70% V
Release [Reset] voltage (initial)
Min.10% V Min.10% V Min.5% V
Time
Characteristics
(initial)
Operate [Set] time (initial)
Max.15 ms Max.20 ms Max.10 ms
Release [Reset] time (initial)
Max.5 ms Max.10 ms Max.5 ms
Expected
life
Mechanical Min.106Min.5 x1072 x107
Electrical Min.105 (5 A 277 V AC)
Min.5 x104 (8 A 277 V AC)
Min.105 (AC)
Min.5 x105 (DC)
105 (3 A 250 V AC, 30 V DC)
5 x104 (5 A 250 V AC, 30 V DC)
Dielectric
strength
(initial)
Between open contacts 1,000 Vrms 1,000 Vrms 1,000 Vrms
Between contact sets 1,000 Vrms
Between contact and coil 4,000 Vrms 2,000 Vrms 3,000 Vrms
Surge withstand voltage
(between contact and coil) (initial) 10,000 V 6,000 V
Ambient temperature -40 to +70-40 to +70 (2c)*2
-40 to +55 (4c) -40 to +90
Protective
construction
Dust cover type −●−
Flux-resistant type ●−−
Sealed type −●●
Dimensions
Height (mm) Including standoff 25 27.8 (Slim), 10.9 (Flat) 12.5
Area of base (mm)
2424
11
11.2
38.14c38.14c
25.42c25.42c
38.14c38.14c
25.4
25.42c25.42c
Slim Flat
55
2020
PC board pattern (BOTTOM VIEW)
indicates input terminal
2.54mm grid
16.5
20
7.5
2φ0.9 2φ1.3
4c
2c2c
Slim Flat
8φ1.2
14φ1.2
4c
14φ1.2
8φ1.2
φ1φ1.2
φ1φ1.2
Safety standards UL/C-UL, TÜV, SEMKO, VDE, CQC UL, CSA UL/C-UL, TÜV
Unit weight (Approx.) 12 g
16 g (2c), 19 g (4c: slim), 18 g (4c: Flat)
3 g
Option Socket, Terminal socket Socket
Remarks *1: Dust cover *2: Min.48 V DC
Initial of part number ALKT AW8 APAN3
30 A
20 A
15 A
10 A
8 A
5 A
3 A
8 A 277 V AC
100 mA 5 V DC
5 A 30 V DC
4c: 4 A 250 V AC*1
2c: 5 A 250 V AC*1
100
μ
A 1 V DC
5 A 30 V DC
5 A 250 V AC
100
μ
A 100
V DC
Power Relays (Over 2A) Selector Chart
 Panasonic Corporation 2018 ASCTB366E 201808
3
Panasonic Corporation
Electromechanical Control Business Division
industrial.panasonic.com/ac/
Category Power Relays (Over 2A)
Product name PQ RELAY PF RELAY DS-P RELAY
Type of relay
(Height includes standoff unit = mm)
1616
10
10
20
20
1515
28
28
5
5
10.510.5
20.2
20.211
11
Features 1 Form A 5A
small size power relay for interface
Compliant with European standards
1a/1c 6A Slim power relays
1a 8A (AC) 1a1b/2a 5A (DC)
small polarized powerrelays
Contact
data
Contact arrangement 1a1a, 1c1a1a1b, 2a
Contact shape Twin Single Single
Contact material AgNi type +Au clad AgNi type, AgNi type +Au plated AgSnO2 type +Au flashed
Contact rating
(resistive)
Min. switching load
(reference value)
Max.switching voltage 250 V AC, 110 V DC (0.3 A) 250 V AC 250 V AC, 125 V DC (0.2 A)
Latching types availability − − ●
Coil data
Rated coil voltage 3, 5, 6, 9, 12, 18, 24V DC 4.5, 5, 6, 9, 12, 18, 24, 48, 60 V DC 3, 5, 6, 9, 12, 24 V DC
Rated operating power 200 mW
170 mW (4.5 to 24 V DC)
217 mW (48 V DC), 175 mW (60 V DC)
300 mW
Operate [Set] voltage (initial)
Max.75% V Max.70% V Max.80% V
Release [Reset] voltage (initial)
Min.5% V Min.5% V Min.10% V [Max.80% V]
Time
Characteristics
(initial)
Operate [Set] time (initial)
Max.20 ms Max.8 ms Max.10 ms
Release [Reset] time (initial)
Max.10 ms Max.4 ms Max.5 ms [Max.10 ms]
Expected
life
Mechanical 2 x107Min.5 x106Min.5 x107
Electrical
Min.2 x10
5
(5 A 125 V AC)
Min.10
5
(5 A 250 V AC, 5 A 30 V DC)
Min.5 x104 (Form A)
Min.3 x104 (Form B) Min.105
Dielectric
strength
(initial)
Between open contacts 1,000 Vrms 1,000 Vrms 1,000 Vrms
Between contact sets 2,000 Vrms
Between contact and coil 4,000 Vrms 4,000 Vrms 3,000 Vrms
Surge withstand voltage
(between contact and coil) (initial) 8,000 V 6,000 V 5,000 V
Ambient temperature -40 to +70-40 to +85-40 to +60 (1a, 2a)
-40 to +65 (1a1b)
Protective
construction
Dust cover type − − −
Flux-resistant type − − −
Sealed type ● ● ●
Dimensions
Height (mm) Including standoff 16 15 10.5
Area of base (mm)
1010
2020 2828
55
1111
20.220.2
PC board pattern (BOTTOM VIEW)
indicates input terminal
2.54mm grid
4φ1.3
1a
1c
21.42
3.78
1.2
5.04
1.9
2φ12φ1.3
21.42
3.78
1.2
5.045.04
1.9
2φ1 3φ1.3
1a
4φ1.2
1a1b, 2a
6φ1.2
Single Stable
Safety standards UL, CSA, VDE UL/C-UL, VDE UL, CSA, TÜV
Unit weight (Approx.) 7 g 5 g 4.5 g
Option Socket Socket
Remarks − − −
Initial of part number APQ3 APF AGP
30 A
20 A
15 A
10 A
8 A
5 A
3 A
5 A 30 V DC
5 A 250 V AC
100
μ
A 100
V DC 1 mA 1 V DC
Au plating
type
6 A 250 V AC
No Au plating
type
100 mA 5 V DC
6 A 250 V AC 5 A 30 V AC
8 A 250 V AC
10 mA 5 V DC
5 A 30 V AC
5 A 250 V AC
10 mA 5 V DC
mew 1 W1 a
Power Relays (Over 2A) Selector Chart
 Panasonic Corporation 2018 ASCTB366E 201808
4
Panasonic Corporation
Electromechanical Control Business Division
industrial.panasonic.com/ac/
Category Power Relays (Over 2A)
Product name DW RELAY LK-Q RELAY ST RELAY
Type of relay
(Height includes standoff unit = mm)15.815.8
2424 1010
18.818.8
10
10
24
24
2525
24
24 11
11
11.311.3
14
14
31
31
Features 1 Form A 8A/16A (TV-8 rated)* ,
small polarized power relays
TV-5/TV-8 rated
1 Form A 5A/8A silent type power
relays
TV-3 rated
1a1b/2a 8A polarized power
relays
Contact
data
Contact arrangement 1a1a1a1b, 2a
Contact shape Single Single Single
Contact material AgSnO2 type AgSnO2 type AgSnO2 type +Au flashed
Contact rating
(resistive)
Min. switching load
(reference value)
Max.switching voltage 250 V AC 277 V AC 277 V AC 250 V AC, 30 V DC
Latching types availability (Latching type only) − ●
Coil data
Rated coil voltage 3, 5, 6, 9, 12, 24 V DC 5, 9, 12, 24 V DC 3, 5, 6, 9, 12, 24, 48 V DC
Rated operating power 200 mW (1 coil latching)
400 mW (2 coil latching) 250 mW Approx 240 mW
Operate [Set] voltage (initial)
Max.80% V Max.80% V Max.80% V
Release [Reset] voltage (initial)
Max.80% V Min.10% V Min.10% V [Max.80% V]
Time
Characteristics
(initial)
Operate [Set] time (initial)
Max.15 ms Max.15 ms Max.15 ms
Release [Reset] time (initial)
Max.15 ms Max.5 ms Max.10 ms [Max.15 ms]
Expected
life
Mechanical Min.106Min.106Min.107
Electrical Min.5 x104Min.2 x104Min.105Min.5 x104Min.105 (8 A 250 V AC)
Dielectric
strength
(initial)
Between open contacts 1,000 Vrms 1,000 Vrms 1,200 Vrms
Between contact sets 2,000 Vrms
Between contact and coil 5,000 Vrms 4,000 Vrms 3,750 Vrms
Surge withstand voltage
(between contact and coil) (initial) 12,000 V 10,000 V 6,000 V
Ambient temperature -40 to +85 (Max.8 A)
-40 to +70 (Max.8 to 16 A) -40 to +70-40 to +60
Protective
construction
Dust cover type −−−
Flux-resistant type ●●−
Sealed type −−●
Dimensions
Height (
mm
) Including standoff
18.8 (Low profile type: 15.8)25 11.3
Area of base (mm)
2424
1010
2424
1111
1414
3131
PC board pattern (BOTTOM VIEW)
indicates input terminal
2.54mm grid
4 or 5φ1.217.5 3.5
7.5
2 coil
latching
only
16.5
20
7.5
2φ0.92φ1.36φ1.4
Single Stable
Safety standards UL/C-UL, VDE, CQC UL/C-UL, TÜV, SEMKO, CQC UL, CSA, VDE
Unit weight (Approx.) 8 g (Low profile type: 7.5 g) 12 g 10 g
Option Socket
Remarks * TV-8 rated and Low profile type:
16 A only − −
Initial of part number ADW ALKQ AR2
30 A
20 A
15 A
10 A
8 A
5 A
3 A
8 A 250 V AC
100 mA 5 V DC
Standard
type
5 A 277 V AC
100 mA 5 V DC
TV-5
8 A 277 V AC
100 mA 5 V DC
TV-8
Inrush type
(Low profile type)
16 A 277 V AC*
100 mA 5 V DC
5 A 30 V DC
8 A 250 V AC
100 m A 5 V DC
Power Relays (Over 2A) Selector Chart
 Panasonic Corporation 2018 ASCTB366E 201808
5
Panasonic Corporation
Electromechanical Control Business Division
industrial.panasonic.com/ac/
Category Power Relays (Over 2A)
Product name DE RELAY DK RELAY DY RELAY
Type of relay
(Height includes standoff unit = mm)
12.512.5
25
25 12.5
12.5
12.512.5
1010
20
20 1515
10
10
20
20
Features
Meet European standards
1a/2a/1a1b 10A/8A polarized
power relays
1a 10A, 1a1b/2a 8A small
polarized power relays
1a 10A, 1a1b 8A small
polarized power relays
Contact
data
Contact arrangement 1a1a1b, 2a1a1a1b, 2a1a1a1b
Contact shape Single Single Single
Contact material AgSnO2 type AgSnO2 type +
Au flashed
AgNi2 type +
Au flashed AgSnO2 type +Au flashed
Contact rating
(resistive)
Min. switching load
(reference value)
Max.switching voltage 250 V AC, 30 V DC 250 V AC, 125 V DC (0.2 A) 250 V AC, 125 V DC (0.2 A)
Latching types availability ●●●
Coil data
Rated coil voltage 5, 12, 24 V DC 3, 5, 6, 9, 12, 24 V DC 3, 5, 6, 9, 12, 24 V DC
Rated operating power 200 mW 200 mW 200 mW
Operate [Set] voltage (initial)
Max.70% V Max.70% V Max.70% V
Release [Reset] voltage (initial)
Min.10% V [Max.70% V] Min.10% V [Max.70% V] Min.10% V [Max.70% V]
Time
Characteristics
(initial)
Operate [Set] time (initial)
Max.10 ms Max.10 ms Max.10 ms
Release [Reset] time (initial)
Max.5 ms [Max.10 ms] Max.8 ms [Max.10 ms] Max.8 ms [Max.10 ms]
Expected
life
Mechanical Min.107Min.5 x107Min.5 x107
Electrical Min.105
Min.5 x104 (2a: 8 A 30 V DC) Min.105Min.105
Dielectric
strength
(initial)
Between open contacts 1,000 Vrms 1,000 Vrms 1,000 Vrms
Between contact sets 4,000 Vrms 4,000 Vrms 4,000 Vrms
Between contact and coil 5,000 Vrms 4,000 Vrms 4,000 Vrms
Surge withstand voltage
(between contact and coil) (initial) 12,000 V 10,000 V 10,000 V
Ambient temperature -40 to +70-40 to +65-40 to +70
Protective
construction
Dust cover type − − −
Flux-resistant type − − −
Sealed type ● ● ●
Dimensions
Height (mm) Including standoff 12.5 10 10
Area of base (mm)
12.512.5
2525 2020
12.51a12.51a
151a1b, 2a151a1b, 2a
2020
15
PC board pattern (BOTTOM VIEW)
indicates input terminal
2.54mm grid
6φ1.2
Single Stable
1a2φ1.1
1a1b, 2a
2φ0.9
4φ1.1
Single Stable
1a2φ1.1
1a1b
2φ0.9
4φ1.1
Single Stable
Safety standards UL/C-UL, VDE UL, CSA, TÜV, VDE UL, CSA, TÜV
Unit weight (Approx.) 7 g 5 g 6 g 6 g
Option Socket Socket
Remarks −−−
Initial of part number ADE AW3 ADY
30 A
20 A
15 A
10 A
8 A
5 A
3 A
10 A 30 V DC
10 A 250 V AC
100 mA 5 V DC
8 A 30 V DC
8 A 250 V AC
100 mA 5 V DC
10 A 30 V DC
10 A 250 V AC
10 mA 5 V DC
8 A 30 V DC
8 A 250 V AC
10 mA 5 V DC
10 A 30 V DC
10 A 250 V AC
10 mA 5 V DC
8 A 30 V DC
8 A 250 V AC
10 mA 5 V DC
Power Relays (Over 2A) Selector Chart
 Panasonic Corporation 2018 ASCTB366E 201808
6
Panasonic Corporation
Electromechanical Control Business Division
industrial.panasonic.com/ac/
Category Power Relays (Over 2A)
Product name LQ RELAY JS RELAY JW RELAY
Type of relay
(Height includes standoff unit = mm)
1010
20
20
1616 16.416.4
2222 16
16
2020
28.628.612.8
12.8
Features 1a/1c 10A small power relays TV-5 rated [1a, 1c (Form A)]
1a/1c 10A cubic type power relays
TV-5 rated (1a)
1a/1c/2a/2c 5A/10A universal
power relays
Contact
data
Contact arrangement 1a, 1c1a, 1c1a Long life 1a, 1c, 2a, 2c1a, 1c
Contact shape Single Single Single
Contact material AgNi type AgSnO2 type 1a: AgSnO2 type
1c, 2a, 2c: AgNi type
Contact rating
(resistive)
Min. switching load
(reference value)
Max.switching voltage 250 V AC 277 V AC, 100 V DC (0.5A) 250 V AC, 30 V DC
Latching types availability − − −
Coil data
Rated coil voltage 5, 6, 9, 12, 18, 24 V DC 5, 6, 9, 12, 18, 24, 48 V DC 5, 6, 9, 12, 24, 48 V DC
Rated operating power 200 mW (1a) , 400 mW (1c) 360 mW 530 mW
Operate [Set] voltage (initial)
Max.75% V Max.70% V Max.70% V
Release [Reset] voltage (initial)
Min.5% V Min.10% V Min.10% V
Time
Characteristics
(initial)
Operate [Set] time (initial)
Max.20 ms Max.10 ms Max.15 ms
Release [Reset] time (initial)
Max.20 ms (With diode) Max.10 ms Max.5 ms
Expected
life
Mechanical Min.107Min.107Min.5 x106
Electrical
Min.5 x104
(Form A: 10 A 125 V AC, 5 A 250 V AC)
Min.105 (Form A: 5 A 30 V DC)
Min.105
(1a, 1c)
Min.2 x105
(1a Long life) Min.105
Dielectric
strength
(initial)
Between open contacts 1,000 Vrms (1a) , 750 Vrms (1c) 750 Vrms 1,000 Vrms
Between contact sets − −
3,000 Vrms (2a, 2c)
Between contact and coil 4,000 Vrms 1,500 Vrms 5,000 Vrms
Surge withstand voltage
(between contact and coil) (initial) 8,000 V 10,000 V
Ambient temperature -40 to +85
-40 to +70 (Class E)
-40 to +85 (Class B)
-40 to +105 (Class F)
-40 to +60 (Class E)
-40 to +85 (Class B)
Protective
construction
Dust cover type − −
Flux-resistant type ● ●
Sealed type ● −
Dimensions
Height (mm) Including standoff 16 16.4 20
Area of base (mm)
1010
2020
16
2222
12.8
28.628.6
PC board pattern (BOTTOM VIEW)
indicates input terminal
2.54mm grid
1a
1c
4φ1.3
5φ1.31c
1a
12
12.2
4
φ
1.3
2
12
12.2
2
5φ1.3
1a
2.420
7.6
4φ1.5
3.5
Safety standards UL/C-UL, VDE, CQC UL, CSA, TÜV, VDE* UL, CSA, VDE, CQC
Unit weight (Approx.) 7 g 12 g 13 g
Option Socket
Remarks * For CQC, please contact our
sales representative
Initial of part number ALQ AJS AJW
30 A
20 A
15 A
10 A
8 A
5 A
3 A
5 A 250 V AC
Form A
10 A 125 V AC
5 A 30 V DC
100 mA 5 V DC 100 mA 5 V DC 100 mA 5 V DC
10 A 277 V AC
Long life
1a
100 mA 5 V DC
10 A 30 V DC
5 A 250 V AC
type
Standard
100 mA 5 V DC
10 A 30 V DC
10 A 250 V AC
type
High capacity
100 mA 5 V DC
6 A 277 V AC
1a, 1c
10 A 125 V AC
1a, 1c
km, 1M1 s m4 1512 s \ Lflflpflg {nia ma m [n];
Power Relays (Over 2A) Selector Chart
 Panasonic Corporation 2018 ASCTB366E 201808
7
Panasonic Corporation
Electromechanical Control Business Division
industrial.panasonic.com/ac/
Category Power Relays (Over 2A)
Product name LK-G RELAY LK-P RELAY SP RELAY
Type of relay
(Height includes standoff unit = mm)
2525
24
24 11
11
2525
24
24 11
11
2222
50
50 25.6
25.6
Features
TV-5 rated
1 mm contact gap.
1 Form A 10A/16A power relays
TV-5 rated
1 Form A 10A power relays
2c 15A, 4c 10A
polarized power relays
Contact
data
Contact arrangement 1a1a2c4c
Contact shape Single Single Twin
Contact material AgSnO2 type AgSnO2 type
Stationary: AgSnO
2
type+Au flashed
Movable: AgSnO
2
type
Contact rating
(resistive)
Min. switching load
(reference value)
Max.switching voltage 277 V AC 277 V AC, 30 V DC 250 V AC, 30 V DC*
Latching types availability − − ●
Coil data
Rated coil voltage 5, 9, 12, 24 V DC 5, 9, 12, 24 V DC 3, 5, 6, 12, 24, 48 V DC
Rated operating power 530 mW 530 mW 300 mW
Operate [Set] voltage (initial)
Max.75% V Max.70% V Max.70% V
Release [Reset] voltage (initial)
Min.10% V Min.10% V Min.10% V [Max.70% V]
Time
Characteristics
(initial)
Operate [Set] time (initial)
Max.15 ms Max.15 ms Max.30 ms
Release [Reset] time (initial)
Max.20 ms (with diode) Max.5 ms Max.20 ms [Max.30 ms]
Expected
life
Mechanical Min.2 x106Min.2 x106Min.5 x107
Electrical Min.105Min.5 x104Min.105Min.105
Dielectric
strength
(initial)
Between open contacts 1,000 Vrms 1,000 Vrms 1,500 Vrms
Between contact sets 3,000 Vrms
Between contact and coil 4,000 Vrms 4,000 Vrms 3,000 Vrms
Surge withstand voltage
(between contact and coil) (initial) 10,000 V 10,000 V
Ambient temperature -40 to +70-40 to +70-50 to +60
Protective
construction
Dust cover type − − ●
Flux-resistant type ● ● −
Sealed type − − −
Dimensions
Height (mm) Including standoff 25 25 22
Area of base (mm)
2424
1111
2424
1111
25.62c
36.84c
5050
PC board pattern (BOTTOM VIEW)
indicates input terminal
2.54mm grid
16.5
20
7.5
2φ0.92φ1.316.5
20
7.5
2φ0.92φ1.3
2c
4c
15.24
10.
16 10.
16 10.
16 10.
16
10φ2.5
15.24
10.
16 10.
16 10.
16 10.
16
16φ2.5
7
.627
.62
Safety standards UL/C-UL, TÜV, CQC UL, CSA, TÜV, SEMKO, VDE, CQC UL, CSA, TÜV
Unit weight (Approx.) 12 g 12 g 50 g 65 g
Option Terminal socket, Mounting board
Remarks *48 V DC (Max.2 A)
Initial of part number ALKG ALKP AR1
30 A
20 A
15 A
10 A
8 A
5 A
3 A
100 mA 5 V DC
16 A 277 V AC
10 A 277 V AC
100 mA 5 V DC
10 A 30 V DC
2c
100 mA 5 V DC
10 A 30 V DC
4c
100 mA 5 V DC
5 A 30 V DC
10 A 277 V AC
100 mA 5 V DC
15 A 250 V AC
10 A 250 V AC
'1 Y
Power Relays (Over 2A) Selector Chart
 Panasonic Corporation 2018 ASCTB366E 201808
8
Panasonic Corporation
Electromechanical Control Business Division
industrial.panasonic.com/ac/
Category Power Relays (Over 2A)
Product name DJ RELAY JV-N RELAY LE RELAY
Type of relay
(Height includes standoff unit = mm)
2929
16.5
16.5
13
13
10.910.9
2222 16
16
24.924.9
12.4
12.4
28.6
28.6
24.924.9
12.4
12.4
28.6
28.6
Features
1-pole/2-pole 16A polarized power relays
Clearance and creepage distance
is Min.8mm (Contact and coil)
1 Form A 16A, low profile: 10.9mm
power relays for heater control
TV-5 rated
1 Form A 16A power relay for
micro wave oven
Contact
data
Contact arrangement 1c, 1a, 1b1a1b, 2c, 2a, 2b1a1a
Contact shape Single Single Single
Contact material AgSnO2 type AgSnO2 type +
Au flashed AgSnO2 type AgSnO2 type
Contact rating
(resistive)
Min. switching load
(reference value)
Max.switching voltage 250 V AC 277 V AC, 110 V DC (0.3 A) 277 V AC
Latching types availability ● − −
Coil data
Rated coil voltage 5, 6, 12, 24, 48 V DC 4.5, 6, 9, 12, 18, 24, 48, 100 V DC 5, 6, 9, 12, 18, 24, 48 V DC
Rated operating power
150 mW (1 coil latching)
250 mW (Single Stable, 2 coil latching)
200 mW (4.5 to 48 V DC)
600 mW (100 V DC)
400 mW (Standard type)
200 mW (High sensitive type)
Operate [Set] voltage (initial)
Max.75% V [Max.70% V] Max.75% V (4.5 to 48 V DC)
Max.60 V DC (100 V DC) Max.75% V
Release [Reset] voltage (initial)
Min.10% V [Max.70% V] Min.5% V (4.5 to 48 V DC)
Min.4 V DC (100 V DC) Min.5% V
Time
Characteristics
(initial)
Operate [Set] time (initial)
Max.20 ms Max.12 ms (4.5 to 48 V DC)
Min.8 ms (100 V DC) Max.20 ms
Release [Reset] time (initial)
Max.20 ms Max.5 ms Max.20 ms (Standard type)
Max.25 ms (High sensitivity type)*
Expected
life
Mechanical Min.5 x106Min. 2 x107Min.2 x106
Electrical Min.105
Min.10
5
(10 A 125 V AC, 10 A 30 V DC)
Min.105
Dielectric
strength
(initial)
Between open contacts 1,000 Vrms 1,000 Vrms 1,000 Vrms
Between contact sets 2,000 Vrms − −
Between contact and coil 4,000 Vrms 2,500 Vrms 4,000 Vrms
Surge withstand voltage
(between contact and coil) (initial) 10,000 V 4,500 V 10,000 V
Ambient temperature -40 to +70
-40 to +70
, -40 to +60
(100 V DC)
-40 to +85
Protective
construction
Dust cover type − − −
Flux-resistant type ● ● ●
Sealed type * − −
Dimensions
Height (mm) Including standoff 16.5 10.9 24.9
Area of base (mm)
2929
13
16
2222
12.4
28.628.6
PC board pattern (BOTTOM VIEW)
indicates input terminal
2.54mm grid
1c
2c
2 coil
latching
only
φ1.5
φ1.5
2 coil
latching
only
2φ0.9
R
R
2
1
2(PC board terminal is also available)
26
7.5
2φ1.3φ1.8
TMP type
Safety standards UL/C-UL, VDE, CQC UL, CSA, TÜV UL, CSA, TÜV, VDE, CQC
Unit weight (Approx.) 14 g 8 g 17 g (15 g PCB type)
Option − − −
Remarks
Test button type is available
* Please contact our sales
representative for details
* With diode
Initial of part number ADJ AJVN ALE
30 A
20 A
15 A
10 A
8 A
5 A
3 A
16 A 277 V AC
100 mA 5 V DC
10 A 30 V DC
10 A 277 V AC
100 mA 5 V DC 100 mA 5 V DC
16 A 125 V AC
16 A 250 V AC
100 mA 5 V DC
10 A 250 V AC
100 mA 5 V DC
Power Relays (Over 2A) Selector Chart
 Panasonic Corporation 2018 ASCTB366E 201808
9
Panasonic Corporation
Electromechanical Control Business Division
industrial.panasonic.com/ac/
Category Power Relays (Over 2A)
Product name LZ RELAY LZ-N RELAY LF RELAY
Type of relay
(Height includes standoff unit = mm)
15.715.7
28.8
28.812.5
12.5
15.715.7
28.8
28.812.5
12.5
23.323.3
15.7
15.7
23.323.3
15.7
15.7
30.130.1
30.130.1
Features
TV-5 rated
Low profile: 15.7mm height
1a/1c 16A power relay
TV-5 rated and meet EN60335-1
GWT Low profile: 15.7mm height
1a/1c 16A power relay
TV-8 rated
1 Form A 20A power relays for
compress or and invertor load
Contact
data
Contact arrangement 1a, 1c1a, 1c1a
Contact shape Single Single Single
Contact material AgSnO2 type AgSnO2 type AgSnO2 type
Contact rating
(resistive)
Min. switching load
(reference value)
Max.switching voltage 440 V AC 440 V AC 250 V AC
Latching types availability − − −
Coil data
Rated coil voltage 5, 9, 12, 18, 24 V DC 5, 9, 12, 18, 24 V DC 5, 6, 9, 12, 18, 24 V DC
Rated operating power 400 mW 400 mW 900 mW
Operate [Set] voltage (initial)
Max.70% V Max.70% V Max.70% V
Release [Reset] voltage (initial)
Min.10% V Min.10% V Min.10% V
Time
Characteristics
(initial)
Operate [Set] time (initial)
Max.15 ms Max.15 ms Max.20 ms
Release [Reset] time (initial)
Max.5 ms Max.5 ms Max.15 ms (With diode)
Expected
life
Mechanical Min.107Min.106Min.2 x106
Electrical Min.105 (Form A)
Min.5 x104 (Form B)
Min.10
5
(Form A) , Min.5 x10
4
(Form C, NO)
Min.10
4
(Form B)
Min.105
Dielectric
strength
(initial)
Between open contacts 1,000 Vrms 1,000 Vrms 1,000 Vrms
Between contact sets − − −
Between contact and coil 5,000 Vrms 5,000 Vrms 5,000 Vrms
Surge withstand voltage
(between contact and coil) (initial) 10,000 V 10,000 V 10,000 V
Ambient temperature -40 to +85 (Class B)
-40 to +105 (Class F)
-40 to +85 (Class B)
-40 to +105 (Class F) -40 to +60
Protective
construction
Dust cover type − − −
Flux-resistant type ● ● ●
Sealed type * − −
Dimensions
Height (mm) Including standoff 15.7 15.7 23.3
Area of base (mm)
12.5
28.828.8
12.5
28.828.8
15.7
30.130.1
PC board pattern (BOTTOM VIEW)
indicates input terminal
2.54mm grid
1a
1c5 5
8φ1.3
7.5
20
5
6φ1.3
7.5
20 1a
1c5 5
8φ1.3
7.5
20
5
6φ1.3
7.5
20
(TMP type is also available)
PC board terminal
1012
12
27.6
13.8
φ2φ2
φ1.8φ1.8
Safety standards UL/C-UL, VDE UL/C-UL, VDE UL/C-UL, TÜV, VDE
Unit weight (Approx.) 12 g 11 g 23 g
Option − − −
Remarks * Please contact our sales
representative for details
Not meeting Electrical Appliance
and Material Safety Act
Initial of part number ALZ ALZN ALF
30 A
20 A
15 A
10 A
8 A
5 A
3 A
16 A 250 V AC
100 mA 5 V DC
20 A 250 V AC
100 mA 5 V DC
16 A 250 V AC
100 mA 5 V DC
TMPtvpe m P (mt u na N , g AD m2 1 a m 1 1 «:4 gm 5‘: w we 9 mm :~ 27w , , 1475 T T 1 M m m m 7,7,, 4 ——V* 1778 177a
Power Relays (Over 2A) Selector Chart
 Panasonic Corporation 2018 ASCTB366E 201808
10
Panasonic Corporation
Electromechanical Control Business Division
industrial.panasonic.com/ac/
Category Power Relays (Over 2A)
Product name JT-V RELAY LF-G RELAY HE RELAY
Type of relay
(Height includes standoff unit = mm)
20.220.2
31.9
31.9
27.927.9
32.2
32.227.4
27.4
PC board
terminal type TMP type
26.926.9
23.323.3
30.1
30.115.7
15.7
35.835.8
33
33
5050
Features Surge withstand voltage: 6KV
1a/1c 30A power relay
1 Form A 22A/33A Compact power
relays for solar inverter load
TV-10/TV-15 rated
1a 30A, 2a 25A power relays
Contact
data
Contact arrangement 1a, 1c1a1a2a
Contact shape Single Single Single
Contact material AgSnO2 type AgSnO2 type AgSnO2 type
Contact rating
(resistive)
Min. switching load
(reference value)
Max.switching voltage 277 V AC 250 V AC 277 V AC, 30 V DC
Latching types availability −−−
Coil data
Rated coil voltage 12, 18, 24, 48 V DC 9, 12, 18, 24 V DC
12, 24, 48, 100/120, 200/240 V AC
6, 12, 24, 48, 100, 110 V DC
Rated operating power 1 W 1.4 W 1.7 to 2.7 VA (AC) , 1.92 W (DC)
Operate [Set] voltage (initial)
Max.75% V Max.70% V Max.70% V
Release [Reset] voltage (initial)
Min.10% V Min.10% V Min.15% V (AC) , Min.10% V (DC)
Time
Characteristics
(initial)
Operate [Set] time (initial)
Max.15 ms Max.20 ms Max.30 ms
Release [Reset] time (initial)
Max.10 ms Max.10 ms Max.30 ms (AC) , Max.10 ms (DC)
Expected
life
Mechanical Min.107Min.105 (Contact gap: 1.5 mm)
Min.5 x105 (Contact gap: 1.8 mm)
Min.5 x106 (AC)
Min.107 (DC)
Electrical Min.105 (Form A)
Min.105 (Form B: 10 A 277 V AC) Min.3 x104 (Standard type) Min.2 x105
(1a: 30 A 250 V AC, 2a: 20 A 250 V AC)
Dielectric
strength
(initial)
Between open contacts 1,200 Vrms 2,500 Vrms 2,000 Vrms
Between contact sets 4,000 Vrms
Between contact and coil 3,500 Vrms 4,000 Vrms 5,000 Vrms
Surge withstand voltage
(between contact and coil) (initial) 6,000 V 6,000 V 10,000 V
Ambient temperature -55 to +85-40 to +60, -40 to +85* -50 to +55
Protective
construction
Dust cover type ●−●
Flux-resistant type ● ● (PC board terminal)
Sealed type ●−−
Dimensions
Height (
mm
) Including standoff
20.2 (PC board terminal)
27.9 (TMP type) 23.3
35.8 (Plug-in terminal type, TM type)
36.3 (PC board terminal)
52.8 (Screw terminal type)
Area of base (mm)
32.2
(31.9)
32.2
(31.9)
27.4
(26.9)
TMP type
( )
The dimensional
drawing
PC board terminal
15.7
30.130.1
( )
The dimensional
drawing
PC board terminal
33
50385038
PC board pattern (BOTTOM VIEW)
indicates input terminal
2.54mm grid
TMP type
1c
1a
15.24
2.54
3.81
17.78
13.97
2φ2.1
2φ1.1
15.24 7.62
2.54
3.81
17.78
13.97
3φ2.1
2φ1.1
1012
12
27.6
13.8
φ2φ2
φ1.8φ1.8
Panel cutout
TM type
2φ4.547.6
Plug-in terminal type
2φ4.540
PC board terminal,
Screw teminal type are also available
Safety standards UL/C-UL UL/C-UL, VDE UL, CSA, VDE, TÜV, CQC
Unit weight (Approx.) 25 g (30 g TMP type) 23 g 80 to 120 g
Option Terminal socket
Remarks Not meeting Electrical Appliance
and Material Safety Act
Not meeting Electrical Appliance
and Material Safety Act
*
Coil holding voltage is 45 to 85%V
Initial of part number AJTV ALFG AHE
30 A
20 A
15 A
10 A
8 A
5 A
3 A
20 A 277 V AC
100 mA 5 V DC 100 mA 5 V DC
22 A 250 V AC
standard
type
100 mA 5 V DC
31 A 250 V AC
High capacity
1.5 mm
gap
type
100 mA 5 V DC
High capacity
1.8 mm
gap
type
33 A 250 V AC 30 A 277 V AC
1a
100 mA 5 V DC
25 A 277 V AC
2a
100 mA 5 V DC
Form A
Power Relays (Over 2A) Selector Chart
 Panasonic Corporation 2018 ASCTB366E 201808
11
Panasonic Corporation
Electromechanical Control Business Division
industrial.panasonic.com/ac/
Category Power Relays (Over 2A)
Product name HE-S RELAY HE RELAY PV TYPE
Type of relay
(Height includes standoff unit = mm)
4040
30
30
36
36
35A48A90A
36.336.3
33
33
38
38
36.336.3
33
33
38
38
38.838.8
33
33
38
38
Features
TV-8 rated
2a/2a1b 35A compact power
relays for energy management
1 Form A 35A/48A/90A compact power relays for solar inverter
Contact
data
Contact arrangement 2a, 2a1b1a
Contact shape Single Single
Contact material AgSnO2 type (Form A)
AgNi type+Au flashed (Form B) AgSnO2 type (35 A) AgNi type (48 A/90 A)
Contact rating
(resistive)
Min. switching load
(reference value)
Max.switching voltage 480 V AC, 110 V DC 277 V AC, 30 V DC 480 V AC
Latching types availability − −
Coil data
Rated coil voltage 6, 9, 12, 24, 48 V DC 6, 9, 12, 24 V DC
Rated operating power 1.88 W 1.92 W
Operate [Set] voltage (initial)
Max.75% V Max.70% V
Release [Reset] voltage (initial)
Min.5% V Min.10% V
Time
Characteristics
(initial)
Operate [Set] time (initial)
Max.30 ms Max.30 ms
Release [Reset] time (initial)
Max.10 ms Max.10 ms
Expected
life
Mechanical Min.5x 106Min.107 (35 A/48 A) Min.106 (90 A)
Electrical
Min.3 x10
4
(Standard type: 35 A 277 V AC)
Min.5 x10
4
(Long life type: 35 A 277 V AC)
Min.3 x104 (35 A: 35 A 277 V AC, 48 A: 48 A 277 V AC)
Min.104 (90 A: 80 A 277 V AC)
Dielectric
strength
(initial)
Between open contacts 2,000 Vrms
(Between open Form A contacts) 2,000 Vrms
Between contact sets 5,000 Vrms
(Between Form A contact sets)
Between contact and coil 5,000 Vrms
(Between Form A contact and coil) 5,000 Vrms
Surge withstand voltage
(between contact and coil) (initial)
10,000 V
(Between From A contact and coil) 10,000 V
Ambient temperature -40 to +55, -40 to +85* -50 to +55, -50 to +85*
Protective
construction
Dust cover type − −
Flux-resistant type ● ●
Sealed type − −
Dimensions
Height (mm) Including standoff 40 36.3 (35 A/48 A) 38.8 (90 A)
Area of base (mm)
30
3636
33
3838
PC board pattern (BOTTOM VIEW)
indicates input terminal
2.54mm grid
2a
2a1b
19
11
4
21.3
7.6
1.6
2‒φ1.6
R0.819
11
4
21.3
7.6
22.9
1.6
2
‒φ
1.6
2
‒φ
2.2
R0.8
48A Type
2ーφ2
8.48.4
18.618.6
2424
32
6.5
1.31.3
90A Type
13.313.3
23.523.5
2020
32
12
1.81.8
1.2
3.63.6
R0.9
R0.6
Safety standards UL/C-UL, VDE UL, CSA, VDE UL/C-UL, VDE
Unit weight (Approx.) 64 g 80 g 85 g
Option − −
Remarks
* Coil holding voltage is 30 to 60%V 90 A type does not meet the Electrical Appliance and Material Safety Law
* Coil holding voltage is 50 to 60%V
Initial of part number AHES AHE
35A Type
6
φ
21
8.48.4
18.618.6
2424
32
4.7
120 A
60 A
50 A
40 A
30 A
20 A
10 A
35 A 277 V AC
Form A
100 mA 5 V DC
35 A 277 V AC
35 A type
100 mA 5 V DC
48 A 277 V AC
48 A type
100 mA 5 V DC
90 A 277 V AC
90 A type
100 mA 5 V DC
1 +7’ V,,
Power Relays (Over 2A) Selector Chart
 Panasonic Corporation 2018 ASCTB366E 201808
12
Panasonic Corporation
Electromechanical Control Business Division
industrial.panasonic.com/ac/
Category Power Relays (Over 2A)
Product name DJ-H RELAY DZ-S RELAY HE-N RELAY
Type of relay
(Height includes standoff unit = mm)
3939
30.230.2
1515 3030
17.5
17.5
38.538.5
4343
40
40
5050
Features 1 form A 50A latching relay for
lighting and motor load
Meet IEC62055-31 UC3
1 form A 90A power latching relay
High capacity 120A 480V AC
1 Form A power relay
Contact
data
Contact arrangement 1a1a1a
Contact shape Single Single Single
Contact material AgSnO2 type AgSnO2 type AgNi type
Contact rating
(resistive)
Min. switching load
(reference value)
Max.switching voltage 480 V AC 276 V AC 800 V AC
Latching types availability (Latching only) (Latching only)
Coil data
Rated coil voltage 5, 12, 24 V DC 5, 12, 24 V DC 6, 9, 12, 24 V DC
Rated operating power 1 W (1 coil latching)
2 W (2 coil latching)
1.5 W (1 coil latching)
3 W (2 coil latching) 2.5 W
Operate [Set] voltage (initial)
Max.75% V Max.70% V Max.75% V
Release [Reset] voltage (initial)
Max.75% V Max.70% V Min.5% V
Time
Characteristics
(initial)
Operate [Set] time (initial)
Max.20 ms Max.20 ms Max.30 ms
Release [Reset] time (initial)
Max.20 ms Max.20 ms Max.10 ms
Expected
life
Mechanical Min.106Min.105Min.106
Electrical Min.104 (50 A 277 V AC)
Min.105 (25 A 277 V AC) Min.104 (90 A 250 V AC) Min.103 (120 A 480 V AC)
Min.104 (55 A 800 V AC)
Dielectric
strength
(initial)
Between open contacts 1,500 Vrms 2,000 Vrms 2,000 Vrms
Between contact sets −−−
Between contact and coil 4,000 Vrms 4,000 Vrms 5,000 Vrms
Surge withstand voltage
(between contact and coil) (initial) 12,000 V 12,000 V 10,000 V
Ambient temperature -40 to +85-40 to +85-40 to +55*1
-40 to +85*2
Protective
construction
Dust cover type −●−
Flux-resistant type ●−●
Sealed type −−−
Dimensions
Height (mm) Including standoff 30.2 17.5 43
Area of base (mm)
3939
15
38.538.5
30
5050
40
PC board pattern (BOTTOM VIEW)
indicates input terminal
2.54mm grid
7.5
27.5 6.75
55
2 or 3φ1.2
2φ2.8
2 coil latching only
25.9
18.75
6
1.2
3.6
32
2.8
R0.3
R
19.419.4
Safety standards UL/C-UL, VDE UL/C-UL, VDE
Unit weight (Approx.) 31 g 45 g 115 g
Option − − −
Remarks Reverse polarity type is available IEC62055-31 UC3
*1: Coil holding voltage is 40 to
100%V (at20℃)
*2: Coil holding voltage is 50 to
60%V (at85℃)
Initial of part number ADJH ADZS AHE6
50 A 277 V AC
100 mA 5 V DC
120 A
60 A
50 A
40 A
30 A
20 A
10 A
120 A 480 V AC
100 mA 5 V DC
100 mA 125 V AC
90 A 250 V AC