Murcia Power Solulions
r: -
'. ' lV-hl
NTV Series
3kVDC Isolated 1W Dual Output SM DC/DC Converters
KDC_NTV.F02 Page 1 of 4
www.murata-ps.com
www.murata-ps.com/support
For full details go to
www.murata-ps.com/rohs
SELECTION GUIDE
Order Code1
Nominal
Input
Voltage
Output
Voltage
Output
Current
Input
Current at
Rated Load
Efficiency Isolation
Capacitance MTTF2
V V mA mA % pF kHrs
NTV0505MC 5 ±5 ±100 282 71 33 1697
NTV0509MC 5 ±9 ±55 260 77 38 682
NTV0512MC 5 ±12 ±42 253 79 44 343
NTV0515MC 5 ±15 ±33 250 80 43 188
NTV1205MC 12 ±5 ±100 114 73 50 559
NTV1209MC 12 ±9 ±55 105 79 72 375
NTV1212MC 12 ±12 ±42 104 80 89 243
NTV1215MC 12 ±15 ±33 101 82 100 154
When operated with additional external load capacitance the rise time of the input voltage will determine the maximum external
capacitance value for guaranteed start up. The slower the rise time of the input voltage the greater the maximum value of the
additional external capacitance for reliable start up.
PRODUCT OVERVIEW
The NTV series of 3kV isolation miniature
surface mounted DC/DC converters employ
leadframe technology and transfer moulding
techniques to bring all of the benefits of IC style
packaging to hybrid circuitry. The co-planar-
ity of the pin positions is based upon IEC
191-6:1990. The devices are suitable for all
applications where high volume production is
envisaged.
FEATURES
RoHS compliant
Efficiency up to 82%
Wide temperature performance at full
1 Watt load, –40°C to 85°C
UL 94V-0 package material
Footprint over pins 1.64cm2
Lead frame technology
Dual isolated output
5V & 12V input
5V, 9V, 12V and 15V output
Internal SMD construction
Toroidal magnetics
Plastic encapsulated
3kVDC isolation (1 minute)
MTTF up to 1.7 million hours
Power density 1.36W/cm3
No heatsink required
Custom solutions available
Multi layer ceramic capacitors
INPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Voltage range Continuous operation, 5V input types 4.5 5 5.5 V
Continuous operation, 12V input types 10.8 12 13.2
Reflected ripple current 41 47 mA p-p
ABSOLUTE MAXIMUM RATINGS
Internal power dissipation 550mW
Input voltage VIN, NTV05 types 7V
Input voltage VIN, NTV12 types 15V
1. If components are required in tape and reel format suffix order code code with -R, e.g. NTV0505MC-R.
2. Calculated using MIL-HDBK-217F with nominal input voltage at full load.
3. 12V input types have typically 3% less load regulation change.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.
OUTPUT CHARACTERISTICS
Parameter Conditions Min. Typ. Max. Units
Rated Power TA=-40°C to 85°C 1.0 W
Voltage Set Point Accuracy See tolerance envelope
Line regulation High VIN to low VIN 1.0 1.2 %/%
Load Regulation3
10% load to rated load, 5V output types 10 12
%
10% load to rated load, 9V output types 6.5 8.0
10% load to rated load, 12V output types 6.0 8.5
10% load to rated load, 15V output types 6.0 7.0
Ripple and Noise
BW=DC to 20MHz, 5V output types 50 75
mV p-p
BW=DC to 20MHz, 9V output types 40 65
BW=DC to 20MHz, 12V output types 40 60
BW=DC to 20MHz, 15V output types 40 60