Option Information
www.vishay.com Vishay Semiconductors
Rev. 2.0, 24-Aug-15 1Document Number: 83713
For technical questions, contact: optocoupleranswers@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT www.vishay.com/doc?91000
Option Information
Optocoupler lead-bend configurations are available as
options. In addition, partial discharge testing as per
VDE / IEC is also available as an option.
See the order information section in the data sheet to
determine if and which options are available to a specific
product. Contact the Vishay sales office for other option
configurations.
The options are:
Option 1 VDE option
Option 6 400 mil (10.16 mm) lead spread DIP configuration
Option 7 Surface mount, gull wing DIP configuration with
standoff
Option 8 Surface mount, gull wing DIP configuration with
increased clearance
Option 9 Surface mount, gull wing DIP configuration
ORDERING OPTIONS
A specific option or combination of options can be ordered
by add the options definition field following the base part
number and CTR range (if applicable) as presented in the
following example:
This field is always 4 characters long and commences with
the character X. In the case of surface mounted products in
tape and reel format, the tape and reel option character “T”
will follow this field.
The possible combinations for these fields (1) are:
X001, X006, X007, X008, X009, X001T
(2), X007T, X008T,
X009T, X016, X017, X018, X019, X017T, X018T, X019T
Notes
(1) Not all options are available for all product types.
(2) The X001T option is only available on products that are available on the following SMD products SFH6106, SFH6156, SFH6186, SFH6206,
and SFH6286 series, e.g. SFH6106-3X001T .
OPTION 1
OPTOCOUPLERS FOR SAFE ELECTRICAL INSULATION PER DIN EN 60747-5-5 (VDE 0884) (1)
The optocoupler listed are suitable for safe electrical
insulation only within the safety maximum ratings.
Compliance with the safety maximum ratings must be
ensured by protective circuits.
The partial discharge measurement ensures that no partial
discharge occurs during operation at maximum permissible
operating insulation voltage (VIORM). Permanent partial
discharge affects the insulating materials and can result in a
high voltage breakdown.
It is recommended that tests with the insulation test voltage
(VISOL) should not be made, otherwise partial discharge may
occur impairing the insulation characteristics. Thus partial
discharges also may occur at the maximum permissible
operating insulation voltage.
The insulation test per DIN EN 60747-5-5 (VDE 0884) is
carried out after all the other tests
18482
SFH615A-3X0
9T
Prefix Base Part Number CTR Ranges Options Definition Tape and
Reel Option
BRT
Il
ILD
ILQ
SFH6
VO
1 = 40 % to 80 %
2 = 63 % to 125 %
3 = 100 % to 200 %
4 = 160 % to 320 %
5 =
or 50 % to 150 % (1)
6 = 100 % to 300 % (1)
7 = 80 % to 160 % (1)
8 = 130 % to 260 % (1)
9 = 200 % to 400 % (1)
250 % to 500 %
Option 1 Optocouplers for safe electr ical
Insulation per DIN VDE 0884
Option 6 Optocouplers with 10.16 mm (0.4")
through hole lead spread
Option 7 Optocouplers with SMD lead form bend,
0.9 mm maximum standoff height
Option 8 Optocouplers with 10.16 mm (0.4") SMD
lead form bend
Option 9 Optocouplers with SMD lead form bend,
0.25 mm maximum standoff height
Option 1 may be combined with the other
lead forming options.
Option T may only be combined with
Options 7, 8, and 9
CNY17F-2X017T
4N35-X016
SFH615-3X001
VO615A-9X007T
Examples:
Note
(1) Used on selected products, consult data sheet for details
0